Physical design optimization of an urban runoff treatment system using Stormwater Management Model (SWMM)
|
| in | Water Science and Technology , Vol. 72 n° 10, 15/11/2015 |
| Auteur(s) : |
J. A. S. Tobio, Auteur (et co-auteur)
M. C. Maniquiz-Redillas, Auteur (et co-auteur) L. H. Kim, Auteur (et co-auteur) |
| Type de document : | Article |
| Sujets : | Eaux pluviales -- Gestion ; Écoulement (hydrologie) ; Métaux lourds -- Aspect environnemental ; Gestion des ressources naturelles |
| Résumé : |
The study presented the application of Stormwater Management Model (SWMM) in determining the optimal physical design properties of an established low impact development (LID) system treating road runoff. The calibration of the model was based on monitored storm events occurring from May 2010 to July 2013. It was found that the total suspended solids was highly correlated with stormwater runoff volume and dominant heavy metal constituents in stormwater runoff, such lead, zinc and copper, with a Pearson correlation coefficient ranging from 0.88 to 0.95 (P < 0.05). Reducing the original ratio of the storage volume to surface area (SV/SA) of the facility and depth by 25% could match the satisfactory performance efficiency achieved in the original design. The smaller SV/SA and depth would [...] The study presented the application of Stormwater Management Model (SWMM) in determining the optimal physical design properties of an established low impact development (LID) system treating road runoff. The calibration of the model was based on monitored storm events occurring from May 2010 to July 2013. It was found that the total suspended solids was highly correlated with stormwater runoff volume and dominant heavy metal constituents in stormwater runoff, such lead, zinc and copper, with a Pearson correlation coefficient ranging from 0.88 to 0.95 (P < 0.05). Reducing the original ratio of the storage volume to surface area (SV/SA) of the facility and depth by 25% could match the satisfactory performance efficiency achieved in the original design. The smaller SV/SA and depth would mean a less costly system, signifying the importance of optimization in designing LID systems. |
| Article en page(s) : | 1747-1753 |
| Langue(s) : | Anglais |
| Lien vers la notice : | https://infodoc.agroparistech.fr/index.php?lvl=notice_display&id=183176 |
Exemplaires (1)
| Localisation | Emplacement | Pôle | Section | Cote | Support | Disponibilité |
|---|---|---|---|---|---|---|
| Montpellier | Bibliothèque | Périodiques Montpellier | sans cote | Papier Périodique | Empruntable Disponible |